Comparing quantitative 177Lu SPECT with scintillation or semiconductor Gamma-Cameras

  • Category: BORDET
  • Swimlane: 2021-2022
  • Column: Done
  • Position: 2
  • Assignee: Olivier Debeir
  • Creator: Olivier Debeir
  • Started:
  • Created: 23/04/2021 12:15
  • Modified: 27/10/2022 10:14
  • Moved: 27/10/2022 10:14
  • 2ndSession
Description

Background
Nuclear medicine examination requires delivery of a gamma-emitting radiopharmaceutical product
into the patient, normally through injection into the bloodstream. The pharmacokinetics of the
radiopharmaceutical in an organ allows studying the biology or the functionality of the considered
organ. The pharmacokinetic is obtained by image quantification of the administered
radiopharmaceutical.

177 Lu is a radioisotope used to produce radiopharmaceutical products for therapeutic purpose because it emits beta particles, but as it also emits gamma rays the treatment could be imaged through gamma-cameras.

Single-photon emission computed tomography (SPECT) is a tomographic imaging technique based on the detection of the gamma rays emitted by the radiopharmaceutical product.

These gamma rays are conventionally detected through scintillation Gamma-Cameras to acquire multiple 2-D images (also called projections) from multiple angles. Software is then used to apply a tomographic reconstruction algorithm to the multiple projections, yielding the 3-D data set (SPECT).

A new generation of Gamma-Camera combining a new type of detectors made of semiconductor and a new type of geometry (ring shape) is now available. This new type of Gamma-Camera is very promising but still needs to be evaluated. (https://www.youtube.com/watch?v=TJzmTjdAMH8)

The Jules Bordet Institute has just acquired the two last generations of these two types of Gamma-Cameras allowing 177 Lu imaging, leading to a unique opportunity to directly compare their capabilities.Goal

The goal of this master thesis is to define the procedure to quantify 3-D images to determine the pharmacokinetic of 131 Iodine administered. First, the Master student will review the available literature on the subject. Secondly, based on literature findings and discussion with the medical physics team and the physician, the student will determine a list of experiment to investigate. Thirdly
she/he will prepare and acquire phantoms (plastic objects that mimics human abdomen) containing activity of 131 Iodine, with activities and geometries corresponding to the previous decisions. Then the student will reconstruct all acquired phantoms with each predefined reconstruction parameters and will perform image quality assurance on quantification. Finally, based on these results, the student will propose the new 3-D procedure for 131 Iodine dosimetry.

Goal

The goal of this master thesis is to compare the efficiency in term of resolution and sensitivity of both systems. First, the Master student will study the available literature on the subject. Secondly, based on literature findings and discussion with the medical physics team, the student will determine a list of experiments to conduct. Thirdly she/he will prepare and acquire phantoms (plastic objects that
mimic the human abdomen) containing activity of 177 Lu, with activities and geometries corresponding to the previous decisions. Then the student will reconstruct all the acquired phantoms with each predefined reconstruction parameters and will perform image quality analysis. Finally, based on
these analyses, the student will compare the two systems.

Promoters:

Gwenaëlle Marin gwennaelle.marin@bordet.be

Bruno Vanderlinden bruno.vanderlinden@bordet.be

Olivier Debeir odebeir@ulb.ac.be

Nicolas Pauly Nicolas.Pauly@ulb.be

Sub-Tasks
Internal links
Comments
Olivier Debeir
Olivier Debeir Created at: 15/09/2021 14:13 Updated at: 15/09/2021 14:13

meeting 15/09/2021
pas de machine
planning examens sur patients 23/11
calibration de la nouvelle machine
cadre médical
réunion sur place à Bordet prévue pour la semaine prochaine

Olivier Debeir
Olivier Debeir Created at: 20/10/2021 13:05 Updated at: 20/10/2021 13:05

meeting Zoom Bordet